<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Optimization of thermoelectric cooler (TEC) : Cooled closed-end oscillating heat pipe charged with degassed, deionized water</title>
  </titleInfo>
  <titleInfo type="uniform">
    <title>Philippine Journal of Agricultural and Biosystems Engineering</title>
  </titleInfo>
  <name type="personal">
    <namePart>De Castro, Leandro T.</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>pages 3-8 col. ill.,  23cm</extent>
  </physicalDescription>
  <note type="statement of responsibility">Leandro T. De Castro and Rizalinda L. De Leon</note>
  <note>A three level, three factor Box-Behnken design of experiment was conducted to determine the optimum operating condition and the effects of heat load, fill ratio and tilt-angle on the performance of a thermoelectric cooler (TEC)-cooled closed-end oscillating heat pipe charged with degassed, deionized water. The fitted quadratic model for thermal resistance, device temperature, and DT evaluated at quasi-steady state condition against heat load of 50 watts to 100 watts, fill ratio of 30% to 70% and tilt-angle of 30 to 90 were significant (a=0.05). The three main effects were found to be significant in all response models except for the inclination angle having no significant effect on all the response variables while the quadratic effect of fill ratio is high for the average evaporator temperature and DT. Simultaneous numerical optimization of thermal resistance and evaporator temperature with the goal to minimize both evaporator temperature and thermal resistance yielded a minimum thermal resistance from 0.07305 to 0.08439 D C/Watts and minimum evaporator temperature from 43.4 to 44.2 C to 58.24 to 60.70 Watts heat load, 37.25 to 38.64% fill ratio, and 90.0 tilt angle. The functional models obtained can be used as basis for comparison with variations of other parameters affecting oscillating heat pipe (OHP) performance. </note>
  <subject authority="lcsh">
    <topic>Box-Behnken</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Optimization</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Oscillating heat pipe (OHP)</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Pulsating Heat Pipe (PHP)</topic>
  </subject>
  <subject authority="lcsh">
    <topic>thermos-electric cooler (TEC)</topic>
  </subject>
  <classification authority="ddc">Per 644 D355 2018</classification>
  <relatedItem type="series">
    <titleInfo>
      <title>14(2018)</title>
    </titleInfo>
  </relatedItem>
  <recordInfo>
    <recordContentSource authority="marcorg"/>
    <recordCreationDate encoding="marc">250904</recordCreationDate>
    <recordChangeDate encoding="iso8601">20250904093352.0</recordChangeDate>
  </recordInfo>
</mods>
