<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02291nam a22002777a 4500</leader>
  <controlfield tag="003">OSt</controlfield>
  <controlfield tag="005">20250904093352.0</controlfield>
  <controlfield tag="008">250904b        |||||||| |||| 00| 0 eng d</controlfield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="c">DSSC</subfield>
  </datafield>
  <datafield tag="082" ind1=" " ind2=" ">
    <subfield code="a">Per 644 D355 2018</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">De Castro, Leandro T. </subfield>
    <subfield code="9">12915</subfield>
  </datafield>
  <datafield tag="130" ind1=" " ind2=" ">
    <subfield code="a">Philippine Journal of Agricultural and Biosystems Engineering </subfield>
    <subfield code="9">12184</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Optimization of thermoelectric cooler (TEC) : Cooled closed-end oscillating heat pipe charged with degassed, deionized water /</subfield>
    <subfield code="c">Leandro T. De Castro and Rizalinda L. De Leon</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">pages 3-8</subfield>
    <subfield code="b">col. ill., </subfield>
    <subfield code="c">23cm</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="a">text</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="a">unmediated </subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="a">volume </subfield>
  </datafield>
  <datafield tag="440" ind1=" " ind2=" ">
    <subfield code="v">14(2018)</subfield>
    <subfield code="x">0119-7312</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">A three level, three factor Box-Behnken design of experiment was conducted to determine the optimum operating condition and the effects of heat load, fill ratio and tilt-angle on the performance of a thermoelectric cooler (TEC)-cooled closed-end oscillating heat pipe charged with degassed, deionized water. The fitted quadratic model for thermal resistance, device temperature, and DT evaluated at quasi-steady state condition against heat load of 50 watts to 100 watts, fill ratio of 30% to 70% and tilt-angle of 30 to 90 were significant (a=0.05). The three main effects were found to be significant in all response models except for the inclination angle having no significant effect on all the response variables while the quadratic effect of fill ratio is high for the average evaporator temperature and DT. Simultaneous numerical optimization of thermal resistance and evaporator temperature with the goal to minimize both evaporator temperature and thermal resistance yielded a minimum thermal resistance from 0.07305 to 0.08439 D C/Watts and minimum evaporator temperature from 43.4 to 44.2 C to 58.24 to 60.70 Watts heat load, 37.25 to 38.64% fill ratio, and 90.0 tilt angle. The functional models obtained can be used as basis for comparison with variations of other parameters affecting oscillating heat pipe (OHP) performance. </subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Box-Behnken</subfield>
    <subfield code="9">12916</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Optimization</subfield>
    <subfield code="9">12427</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Oscillating heat pipe (OHP)</subfield>
    <subfield code="9">12917</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Pulsating Heat Pipe (PHP)</subfield>
    <subfield code="9">12918</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">thermos-electric cooler (TEC)</subfield>
    <subfield code="9">12919</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">ddc</subfield>
    <subfield code="c">PINDEX</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">9209</subfield>
    <subfield code="d">9209</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">ddc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">SPMT-CAS</subfield>
    <subfield code="b">SPMT-CAS</subfield>
    <subfield code="d">2025-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">Per 644 D355 2018</subfield>
    <subfield code="r">2025-09-04 00:00:00</subfield>
    <subfield code="w">2025-09-04</subfield>
    <subfield code="y">PINDEX</subfield>
  </datafield>
</record>
