Optimization of thermoelectric cooler (TEC) : Cooled closed-end oscillating heat pipe charged with degassed, deionized water / (Record no. 9209)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02291nam a22002777a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | OSt |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250904093352.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250904b |||||||| |||| 00| 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | DSSC |
| 082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
| Classification number | Per 644 D355 2018 |
| 100 ## - MAIN ENTRY--PERSONAL NAME | |
| Personal name | De Castro, Leandro T. |
| 9 (RLIN) | 12915 |
| 130 ## - MAIN ENTRY--UNIFORM TITLE | |
| Uniform title | Philippine Journal of Agricultural and Biosystems Engineering |
| 9 (RLIN) | 12184 |
| 245 ## - TITLE STATEMENT | |
| Title | Optimization of thermoelectric cooler (TEC) : Cooled closed-end oscillating heat pipe charged with degassed, deionized water / |
| Statement of responsibility, etc | Leandro T. De Castro and Rizalinda L. De Leon |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | pages 3-8 |
| Other physical details | col. ill., |
| Dimensions | 23cm |
| 336 ## - CONTENT TYPE | |
| Content type term | text |
| 337 ## - MEDIA TYPE | |
| Media type term | unmediated |
| 338 ## - CARRIER TYPE | |
| Carrier type term | volume |
| 440 ## - SERIES STATEMENT/ADDED ENTRY--TITLE | |
| Volume number/sequential designation | 14(2018) |
| International Standard Serial Number | 0119-7312 |
| 500 ## - GENERAL NOTE | |
| General note | A three level, three factor Box-Behnken design of experiment was conducted to determine the optimum operating condition and the effects of heat load, fill ratio and tilt-angle on the performance of a thermoelectric cooler (TEC)-cooled closed-end oscillating heat pipe charged with degassed, deionized water. The fitted quadratic model for thermal resistance, device temperature, and DT evaluated at quasi-steady state condition against heat load of 50 watts to 100 watts, fill ratio of 30% to 70% and tilt-angle of 30 to 90 were significant (a=0.05). The three main effects were found to be significant in all response models except for the inclination angle having no significant effect on all the response variables while the quadratic effect of fill ratio is high for the average evaporator temperature and DT. Simultaneous numerical optimization of thermal resistance and evaporator temperature with the goal to minimize both evaporator temperature and thermal resistance yielded a minimum thermal resistance from 0.07305 to 0.08439 D C/Watts and minimum evaporator temperature from 43.4 to 44.2 C to 58.24 to 60.70 Watts heat load, 37.25 to 38.64% fill ratio, and 90.0 tilt angle. The functional models obtained can be used as basis for comparison with variations of other parameters affecting oscillating heat pipe (OHP) performance. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name as entry element | Box-Behnken |
| 9 (RLIN) | 12916 |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name as entry element | Optimization |
| 9 (RLIN) | 12427 |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name as entry element | Oscillating heat pipe (OHP) |
| 9 (RLIN) | 12917 |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name as entry element | Pulsating Heat Pipe (PHP) |
| 9 (RLIN) | 12918 |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name as entry element | thermos-electric cooler (TEC) |
| 9 (RLIN) | 12919 |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Periodical Indexing |
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Date acquired | Total Checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | DSSC LEARNING RESOURCE CENTER | DSSC LEARNING RESOURCE CENTER | 2025-09-04 | Per 644 D355 2018 | 2025-09-04 | 2025-09-04 | Periodical Indexing |